PPRROOBBLLEEMM:: LLOOWW OOUUTTPPUUTT VVOOLLTTAAGGEE
Possible causes
Using average-reading voltmeter.
Inverter is overloaded.
Input voltage below 9.5 volts.
Suggested remedy
Use true RMS reading meter for the following:
Reduce load to a maximum of 100 watts to maintain regula-
tion.
Keep input voltage above 9.5 volts to maintain regulation.
PPRROOBBLLEEMM:: LLOOWW BBAATTTTEERRYY AALLAARRMM OONN AALLLL TTHHEE TTIIMMEE
Possible causes
Poor battery condition.
Inadequate input power or excessive load.
Suggested remedy
Replace battery.
Check the voltage at the cigarette lighter plug and socket.
Clean or replace as necessary to correct for low voltage.